PROFILE RADIOGRAPHY
Profile Radiography, technically called Tangential radiography is a radiographic technique used for the determination of remaining pipe wall thickness. Wall thickness measurement in processing pipe is necessary to determine loss of material due corrosion under insulation and internal erosion. Thickness measurement would assist the engineer in making decisions with regards to the safety of plant, environment and personnel and also for insurance purposes.
INSPECTION METHODS
Conventional Gamma Radiography
Conventional X-Radiography
Digital Radiography (DRT)
Computed Radiography (CRT)
PERSONNEL QUALIFICATIONS
API Piping Inspector (API 570)
TRACK RECORD
Shell Eastern Petroleum, Bukom Terminal (Open Vision, Profile Radiography
MISC Malaysia (Computed Radiography)